CASE STUDY · APPROVED

Rear infill extension and sliding doors to a ground floor flat

Pellant Road, Fulham · London Borough of Hammersmith and Fulham

Planning permission was sought for a small infill extension to the side and rear of the back addition of a ground floor flat, with a rooflight on its flat roof and sliding doors to the side elevation in place of an existing door and window. We prepared the Design and Access Statement, the drawings and a Flood Risk Assessment.

Side return of the flat, with the door and window to be replaced by sliding doors outlined (Design and Access Statement)
Side return of the flat, with the door and window to be replaced by sliding doors outlined (Design and Access Statement)

The site

The site is a two-storey mid-terrace building converted into two flats, and the application relates only to the ground floor flat. It is not in a conservation area, and the rear of the site borders the grounds of a primary school. The Environment Agency flood map places the site in Flood Zone 3, in an area benefiting from flood defences, at about 4.6m above sea level.

The challenge

The extension had to add usable space without affecting neighbours or the street, using an unused and inaccessible lightwell at the rear of the back addition. Because the site is in Flood Zone 3 and at medium risk of surface water flooding, a site-specific Flood Risk Assessment was needed even for a minor extension.

What was submitted

  1. Design and Access StatementDescribed a 1.2m x 1.57m infill into the rear lightwell, adding 1.8 square metres of gross internal area. This enlarges the kitchen and dining area, relocates the bathroom to the rear and adds a skylight. The extension keeps the existing roofline of the single-storey rear addition and would not be visible from the street.
  2. Design and Access Statement – glazing and layoutProposed double-glazed units in keeping with the existing windows, with sliding doors replacing a door and window to bring more light into the living space. The statement noted the building's planning history, 1981/01868/FUL, approving its use as two self-contained flats.
  3. Flood Risk AssessmentRecorded medium surface water risk (1% to 3.3% annual chance), very low risk from rivers or the sea, reservoir flood depths below 0.3m, and Kempton Park Gravel over London Clay. The new floor level matches the existing rear addition, 170mm above ground. Resilience measures included non-return valves, sockets 1200mm above floor level, a sump pump and water-resistant fittings.

Outcome

The London Borough of Hammersmith and Fulham approved the infill extension on 20 April 2021.

Images and findings are taken from the documents submitted with the planning application. The full application is available on the council's planning register.

YOUR NEXT STEP

Planning something similar?

Tell us about the site and what you want to achieve. We will tell you which reports the council is likely to need and what they should cost.

Call 020 8004 4464 or email info@greencodeconsultants.com.